Collinson Online UPS PR63RT6KP

$7,247.63 (GST inclusive)

»Collinson Online UPS PR63RT6KP
»Nominal Voltage: 208 / 220 / 230 / 240Vac
»Voltage Range: 110-276Vac
»Waveform (Battery Mode): Pure Sine Wave
»Typical Transfer Time: 0ms
»Power Factor: 0.99
»Capacity: 6000VA/6000W
»Dimension (W x D x H)
UPS Module: 438 mm x 131 mm x 680 mm
Battery Module: 438 mm x 131 mm x 680 mm
»Net Weight
UPS Module: 17.7 kg
Battery Module: 62.90 kg
»Warranty: 2 years limited warranty from manufacturing defects

Description

Online Double Conversion UPS

for critical IT environments

The PRO 63RT Premium series online UPS is the first UPS in its class to provide a unity power factor whereby VA = W. With an output power factor of 1.0, the PRO 63RT Premium series delivers at least 11% more power than any other UPS with equivalent VA ratings and lower power factors, thus it can power more servers and equipment.

A proven and reliable online UPS, the PRO 63RT Premium series uses double-conversion topology for continuous power conditioning. When your business and mission critical systems require runtime in hours, not minutes, the PRO 63RT Premium UPS can also be expanded with additional external battery modules to support your overall business continuity goals.

With the availability of its HID USB, RS232, SNMP and Emergency Power Off (EPO), the PRO 63RT Premium UPS integrates seamlessly into IT environments, especially for servers, switches, voices or data networks, online storage systems and other critical equipment.

Technical Specification of PRO 63RT Premium Series (Rack/Tower Convertible) *

Model NumberPR63RT6KPPR63RT10KP
Capacity6000VA/6000W10000VA/10000W
Input
Nominal Voltage208 / 220 / 230 / 240Vac
Voltage Range110 - 276Vac
Nominal Frequency50Hz / 60 Hz (Auto Sensing)
Frequency Range(46 to 55) / (54 to 66) Hz
Power Factor0.98
Output
Nominal Voltage (Battery Mode)208 / 220 / 230 / 240Vac
Voltage Regulation± 1%
Nominal Output Frequency50Hz / 60Hz
Frequency Range (Battery) ± 0.5Hz
WaveformPure Sine Wave
THDv≤ 2%@linear load,  ≤ 5%@non-linear load
Current Crest Ratio3 :1
Transfer Time0 ms
Oberload Protection - Line Mode105% to 125%: transfer to bypass after 10min
125% to 150%:  transfer to bypass after 1min
> 150%: Transfer to bypass immediately
Oberload Protection - Battery Mode105% to 125%: shut down after 1 min
> 125%: shutdown immediately
Oberload Protection - Bypass Mode125% to 150%: After 1 min, alarm sounds continuously and output is cut off
150% to 170%: After 10s, alarm sounds continuously and output is cut off
> 170%: After 1s, alarm sounds continuously and output is cut off
Output ConnectionStandard UPS Module: 6 x C13, 4 x C19
UPS Module with parallel redundancy option: Terminal block
Battery
Battery TypeMaintenance free
Battery Voltage240VDC
Charging Current1A
Recharge Time to 90%
(based on 1 battery module)
7H
Efficiency
Efficiency (Inverter Mode)92%
Efficiency (Battery Mode)90%
ECO Mode96%
Indicators
DisplayLCD
AlarmsBattery Mode, Low Battery, Overload, Fault, etc
Interface
RS232Yes
HID Compliant USB PortYes
EPOYes
SNMPOptional
Management
Auto RechargeYes
Auto RestartYes
Outlet Programmable ManagementYes
Parallel Operation (Optional)Up to 4 units (only for UPS module with terminal block output)
Maintenace Bypass (Optional)Available with Power Gateway series
Power Management SoftwareYes
Compliance
CertificationCE
Physical
Dimension (W x H x D)UPS Module: 438 mm x 131 mm x 680 mm
Battery Module: 438 mm x 131 mm x 680 mm
Net WeightUPS Module: 17.7 kg
Battery Module: 62.90 kg
UPS Module: 20.50 kg
Battery Module: 62.90 kg
Environment
Operating  Humidity0-90% non-condensing
Operating Temperature0- 40°C
Noise Level< 60 dB

* Specifications subject to change(s) without prior notification.

Warranty: 2 years limited warranty from manufacturing defects